← Të gjitha produktet

Shtëpi inteligjente & KNX / Ndërfaqe lidhëse (gateway)

Intesis York VRF systems to Modbus TCP/RTU Application — IN770AIR00MO000_MBS_YRK

Intesis · IN770AIR00MO000_MBS_YRK

Pyesni për këtë produktPërmbledhje teknike · Printo / ruaj si PDF

Përshkrimet dhe të dhënat teknike shfaqen në gjuhën në të cilën janë dhënë.

The York application allows bidirectional control and monitoring of York VRF systems from a BMS, SCADA, PLC, or any controller working as a Modbus client. This solution allows the integration of up to 64 indoor units.

Foto 1 nga 1

Intesis York VRF systems to Modbus TCP/RTU Application — IN770AIR00MO000_MBS_YRK — manufacturer representative image

Specifikimet teknike

Manufacturer reference: IN770AIR00MO000_MBS_YRK Product scope: Manufacturer article or reference; confirm the required configuration when ordering. Net Width (mm): 106 mm Net Height (mm): 90 mm Net Depth (mm): 58 mm Net Weight (g): 194 g Mounting: DIN rail mount (bracket included), Wall mount Input Voltage (V): For DC: 12 .. 36 VDC ±10%, Max: 250 mA For AC: 24 VAC ±10 %, 50-60 Hz, Max: 127 mA Recommended voltage: 24 VDC, Max: 127 mA Power Consumption (W): 3 Power Connector: 3-pole Operating Temperature °C Min: 0o °C Operating Temperature °C Max: 60o °C Storage Temperature °C Min: -30 °C Storage Temperature °C Max: 60 °C Housing Materials: Plastic Installation Conditions: This gateway is designed to be mounted inside an enclosure. If the unit is mounted outside an enclosure, precautions should always be taken to prevent electrostatic discharge to the unit. When working inside an enclosure (e.g., making adjustments, setting switches, etc.), typical anti-static precautions should always be followed before touching the unit. Capacity: M: Up to 64 indoor units Configuration: Intesis MAPS Dual Usage: No LED Indicators: Gateway and communication status. DIP & Rotary Switches: EIA-485 serial port configuration. Push Buttons: Factory reset. I-Am message (for BACnet only). Normal mode/programming mode switch (for KNX only). Connectors / Input / Output: Power supply, EIA-485, KNX, Ethernet, HVAC port, Binary inputs (dry contact), Console port USB. Contains Battery: No Product Power Connectors: 3-pole Network Interface 1: Modbus Network Interface 2: Modbus Product image: Manufacturer-assigned image shared by multiple catalogue references. Confirm the selected configuration and finish when requesting a quotation. Manufacturer / product source: https://www.hms-networks.com/p/in770air00mo000-mbs-yrk-york-vrf-systems-to-modbus-tcp-rtu-application

Krahasoni produktet dhe planifikoni projektin

Krahasoni produktet e përshtatshme dhe diskutoni përzgjedhjen me ekipin tonë. Konfirmoni specifikimet dhe përputhshmërinë përpara porosisë.

Ju intereson ky produkt?

Na kontaktoni për disponueshmërinë, çmimet dhe ndihmë me projektin tuaj.

Ose na shkruani drejtpërdrejt me email